National Repository of Grey Literature 5 records found  Search took 0.00 seconds. 
Photometry and spectroradiometry of LEDs
Vysoudil, Martin ; Škoda, Jan (referee) ; Drápela, Jiří (advisor)
This thesis deals with the processing of light technical parameters and performance of key LED chips for their applications in lighting systems. The aim is to create a laboratory model for measuring the qualitative and quantitative parameters of highly luminous light LED emitted depending on the angle, using a spherical integrator 0.3 m, goniometer and fiber spektroradiometr /luxmeters. Goniometer is designed using modular optomechanical parts company Thorlabs. Due to the current passing through the LED chips heat up considerably. To light LED chip parameters tested were not affected by heat from the chip is required to pay the heat generated by a passive radiator. Another part of this thesis is the reconstruction of an older model spherical integrator. Reconstruction must be undertaken so as to ensure sufficient cooling again tested LEDs. Light scattered in the ball of the integrator is led by the optical cable to the spektroradiometr that are subsequently recorded its parameters. The second element used to measure the light produced by the LED source is photocell. Spherical integrator must be appropriately modified to indicate the two measuring elements and also meet the standards of determining the correctness of measurement. At the end of the measurement results will be compared with catalog values provided by the manufacturer.
Testing of MEMS gyroscopes
Hasík, Stanislav ; Vágner,, Martin (referee) ; Klusáček, Stanislav (advisor)
This diploma thesis presents theoretical information regarding MEMS gyroscopes their parameters and designs. The description of measurement chain be used for testing of MEMS gyroscopes in Honeywell International s.r.o. is presented. Special focus is devoted to: the Polytec MSA-500 system, the Standa goniometers and their controller, Peltier cell and its driver. The practical part of this thesis contains the description of the thermal control system and also the description of the developed “Measurement system” in the LabVIEW software which is used for controlling the goniometers position and the Peltier cell. The system is able to fully control two goniometer stages, align the surface of tested MEMS device to orthogonal position with respect to the Polytec MSA-500 measurement head and also control the temperature of the tested device. The last part of this thesis presents the tests of the MEMS gyroscope parameters with special focus to the MEMS gyroscope angle random walk and the bias dependence on the vacuum quality of the structure environment.
The construction for the innovative Jecklin Disk microphone technique
Strážnický, Martin ; Musil, Jaroslav (referee) ; Jirásek, Ondřej (advisor)
The thesis deals with the design and subsequent measurement of the parameters of the Jecklin disc pair microphone array. The theoretical part deals with human hearing, microphone characteristics and types of stereo microphone technology. The practical part focuses on the measurement of the directivity and width of the stereo image when changing the configuration of the array. The measured results are then verified in practice by recording acoustic musical instruments.
Testing of MEMS gyroscopes
Hasík, Stanislav ; Vágner,, Martin (referee) ; Klusáček, Stanislav (advisor)
This diploma thesis presents theoretical information regarding MEMS gyroscopes their parameters and designs. The description of measurement chain be used for testing of MEMS gyroscopes in Honeywell International s.r.o. is presented. Special focus is devoted to: the Polytec MSA-500 system, the Standa goniometers and their controller, Peltier cell and its driver. The practical part of this thesis contains the description of the thermal control system and also the description of the developed “Measurement system” in the LabVIEW software which is used for controlling the goniometers position and the Peltier cell. The system is able to fully control two goniometer stages, align the surface of tested MEMS device to orthogonal position with respect to the Polytec MSA-500 measurement head and also control the temperature of the tested device. The last part of this thesis presents the tests of the MEMS gyroscope parameters with special focus to the MEMS gyroscope angle random walk and the bias dependence on the vacuum quality of the structure environment.
Photometry and spectroradiometry of LEDs
Vysoudil, Martin ; Škoda, Jan (referee) ; Drápela, Jiří (advisor)
This thesis deals with the processing of light technical parameters and performance of key LED chips for their applications in lighting systems. The aim is to create a laboratory model for measuring the qualitative and quantitative parameters of highly luminous light LED emitted depending on the angle, using a spherical integrator 0.3 m, goniometer and fiber spektroradiometr /luxmeters. Goniometer is designed using modular optomechanical parts company Thorlabs. Due to the current passing through the LED chips heat up considerably. To light LED chip parameters tested were not affected by heat from the chip is required to pay the heat generated by a passive radiator. Another part of this thesis is the reconstruction of an older model spherical integrator. Reconstruction must be undertaken so as to ensure sufficient cooling again tested LEDs. Light scattered in the ball of the integrator is led by the optical cable to the spektroradiometr that are subsequently recorded its parameters. The second element used to measure the light produced by the LED source is photocell. Spherical integrator must be appropriately modified to indicate the two measuring elements and also meet the standards of determining the correctness of measurement. At the end of the measurement results will be compared with catalog values provided by the manufacturer.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.